1.
Curr Eye Res ; 49(3): 260-269, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38078692

RESUMO

PURPOSE: The study showcased the application of the lab-assembled HPLC-LED-IF system to analyze proteins in tear fluid samples collected from individuals diagnosed with primary open-angle glaucoma (POAG). METHODS: Clinical application of the said technique was evaluated by recording chromatograms of tear fluid samples from control and POAG subjects and by analyzing the protein profile using multivariate analysis. The data analysis methods involved are principal component analysis (PCA), Match/No-Match, and artificial neural network (ANN) based binary classification for disease diagnosis. RESULTS: Mahalanobis distance and spectral residual values calculated using a standard calibration set of clinically confirmed POAG samples for the Match/No-Match test gave 86.9% sensitivity and 81.8% specificity. ANN with leaving one out procedure has given 87.1% sensitivity and 81.8% specificity. CONCLUSION: The results of the study revealed that the utilization of a 278 nm LED excitation in the HPLC system offers good sensitivity for detecting proteins at low concentrations allowing to obtain reliable protein profiles for the diagnosis of POAG.


Assuntos
Glaucoma de Ângulo Aberto , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Cromatografia Líquida de Alta Pressão , Projetos de Pesquisa , Análise Multivariada , Redes Neurais de Computação
2.
ACS Sens ; 8(11): 4111-4120, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37871260

RESUMO

Breath analysis is emerging as a universal diagnostic method for clinical applications. The possibility of breath analysis is being explored vigorously using different analytical techniques. We have designed and assembled a multiwavelength UV photoacoustic spectroscopy (PAS) sensor for the said application. To optimize laser wavelength for sample excitation, photoacoustic signals from disease and normal conditions are recorded with different laser excitations (213, 266, 355, and 532 nm) on exhaled breath samples. Principal component analysis (PCA) of the PA signals has shown that 213, 266, and 355 nm laser excitations are suitable for breath analysis, with reliable descriptive statistics obtained for 266 nm laser. The study has, therefore, been extended for breath samples collected from asthma, chronic obstructive pulmonary disease (COPD), and normal subjects, using 266 nm laser excitation. PCA of the PA data shows good classification among asthma, COPD, and normal subjects. Match/No-match study performed with asthma, COPD, and normal calibration set has demonstrated the potential of using this method for diagnostic application. Sensitivity and specificity are observed as 88 and 89%, respectively. The area under the curve of the ROC curve is found to be 0.948, which justifies the diagnostic capability of the device for lung diseases. The same samples were studied using a commercial E-Nose, and the measurement outcome strongly supports the PAS results.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Asma/diagnóstico , Curva ROC , Análise Espectral
3.
Biophys Rev ; 14(4): 1023-1050, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35996626

RESUMO

Cardiovascular diseases (CVD) are the major causative factors for high mortality and morbidity in developing and developed nations. The biomarker detection plays a crucial role in the early diagnosis of several non-infectious and life-threatening diseases like CVD and many cancers, which in turn will help in more successful therapy, reducing the mortality rate. Biomarkers have diagnostic, prognostic and therapeutic significances. The search for novel biomarkers using proteomics, bio-sensing, micro-fluidics, and spectroscopic techniques with good sensitivity and specificity for CVD is progressing rapidly at present, in addition to the use of gold standard biomarkers like troponin. This review is dealing with the current progress and prospects in biomarker research for the diagnosis of cardiovascular diseases. Expert opinion. Fast diagnosis of cardiovascular diseases (CVDs) can help to provide rapid medical intervention, which can affect the patient's short and long-term health. Identification and detection of proper biomarkers for early diagnosis are crucial for successful therapy and prognosis of CVDs. The present review discusses the analysis of clinical samples such as whole blood, blood serum, and other body fluids using techniques like high-performance liquid chromatography-LASER/LED-induced fluorescence, Raman spectroscopy, mainly, optical methods, combined with nanotechnology and micro-fluidic technologies, to probe patterns of multiple markers (marker signatures) as compared to conventional techniques.

4.
Anal Bioanal Chem ; 414(12): 3617-3624, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35303135

RESUMO

There is an urgent need to have reliable technologies to diagnose post-coronavirus disease syndrome (PCS), as the number of people affected by COVID-19 and related complications is increasing worldwide. Considering the amount of risks associated with the two chronic lung diseases, asthma and chronic obstructive pulmonary disease (COPD), there is an immediate requirement for a screening method for PCS, which also produce symptoms similar to these conditions, especially since very often, many COVID-19 cases remain undetected because a good share of such patients is asymptomatic. Breath analysis techniques are getting attention since they are highly non-invasive methods for disease diagnosis, can be implemented easily for point-of-care applications even in primary health care centres. Electronic (E-) nose technology is coming up with better reliability, ease of operation, and affordability to all, and it can generate signatures of volatile organic compounds (VOCs) in exhaled breath as markers of diseases. The present report is an outcome of a pilot study using an E-nose device on breath samples of cohorts of PCS, asthma, and normal (control) subjects. Match/no-match and k-NN analysis tests have been carried out to confirm the diagnosis of PCS. The prediction model has given 100% sensitivity and specificity. Receiver operating characteristics (ROC) has been plotted for the prediction model, and the area under the curve (AUC) is obtained as 1. The E-nose technique is found to be working well for PCS diagnosis. Our study suggests that the breath analysis using E-nose can be used as a point-of-care diagnosis of PCS.Trial registrationBreath samples were collected from the Kasturba Hospital, Manipal. Ethical clearance was obtained from the Institutional Ethics Committee, Kasturba Medical College, Manipal (IEC 60/2021, 13/01/2021) and Indian Council of Medical Research (ICMR) (CTRI/2021/02/031357, 06/02/2021) Government of India; trials were prospectively registered.


Assuntos
Asma , COVID-19 , Compostos Orgânicos Voláteis , Asma/diagnóstico , Testes Respiratórios/métodos , COVID-19/diagnóstico , Nariz Eletrônico , Expiração , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Tecnologia , Compostos Orgânicos Voláteis/análise